Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - AB60F AUTOMATIC TRANSMISSION / TRANSAXLE

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT NO. 2 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)

CHECK HARNESS AND CONNECTOR (NO. 2 TRANSMISSION WIRE - ECM)

INSPECT SHIFT SOLENOID VALVE SL2

DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

DESCRIPTION

Shifting from 1st to 6th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely ().

DTC CodeDTC Detection ConditionTrouble Area
P0778The ECM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears (1 trip detection logic).
The output signal duty ratio equals 100% (the SL2 output signal duty ratio is less than 100% under normal conditions).
Open or short in shift solenoid valve SL2 circuit
Shift solenoid valve SL2
ECM

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other normally functioning shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the open or short circuited solenoid.


While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL2 circuit, the ECM determines there is a malfunction ().


WIRING DIAGRAM

Dtc P0778  Pressure Control Solenoid B Electrical (Shift Solenoid Valve Sl2). AB60F AUTOMATIC TRANSMISSION / TRANSAXLE. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

INSPECTION PROCEDURE

  • HINT:
  • The shift solenoid valve SL2 is turned ON/OFF normally when the shift lever is in D:
ECM gear shift command1st2nd3rd4th5th6th
Shift solenoid valve SL2ONONONONOFFOFF
1.INSPECT NO. 2 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)
Dtc P0778  Pressure Control Solenoid B Electrical (Shift Solenoid Valve Sl2). AB60F AUTOMATIC TRANSMISSION / TRANSAXLE. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the No. 2 transmission wire connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    2 (SL2+) - 4 (SL2-)20°C (68°F)5.0 to 5.6 Ω
    2 (SL2+) - Body groundAlways10 kΩ or higher
    4 (SL2-) - Body groundAlways10 kΩ or higher
Text in Illustration
*aComponent without harness connected
(No. 2 Transmission Wire)
NG
Go to step 3
OK
2.CHECK HARNESS AND CONNECTOR (NO. 2 TRANSMISSION WIRE - ECM)
Dtc P0778  Pressure Control Solenoid B Electrical (Shift Solenoid Valve Sl2). AB60F AUTOMATIC TRANSMISSION / TRANSAXLE. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the ECM connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • for LHD
    Tester ConnectionConditionSpecified Condition
    C45-12 (SL2+) - C45-13 (SL2-)20°C (68°F)5.0 to 5.6 Ω
    C45-12 (SL2+) - Body groundAlways10 kΩ or higher
    C45-13 (SL2-) - Body groundAlways10 kΩ or higher
  • for RHD
    Tester ConnectionConditionSpecified Condition
    C46-12 (SL2+) - C46-13 (SL2-)20°C (68°F)5.0 to 5.6 Ω
    C46-12 (SL2+) - Body groundAlways10 kΩ or higher
    C46-13 (SL2-) - Body groundAlways10 kΩ or higher
Text in Illustration
*1for LHD
*2for RHD
*aFront view of wire harness connector
(to ECM)
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE ECM ()
3.INSPECT SHIFT SOLENOID VALVE SL2
Dtc P0778  Pressure Control Solenoid B Electrical (Shift Solenoid Valve Sl2). AB60F AUTOMATIC TRANSMISSION / TRANSAXLE. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Remove the shift solenoid valve SL2.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    1 - 220°C (68°F) 5.0 to 5.6 Ω

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

  • OK:
  • Measurement ConditionSpecified Condition
    Battery positive (+) with a 21 W bulb → Terminal 1
    Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise
Text in Illustration
*aComponent without harness connected
(Shift Solenoid Valve SL2)
NG
REPLACE SHIFT SOLENOID VALVE SL2 ()
OK
REPAIR OR REPLACE NO. 2 TRANSMISSION WIRE ()