Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS

YAW RATE AND DECELERATION SENSOR (w/ VSC) - INSTALLATION

1. INSTALL YAW RATE SENSOR

Connect the sensor connector, and then attach the clamp to the hole of the sensor bracket.

  • NOTICE:
  • Securely connect the connector.

Install the yaw rate sensor with the 2 bolts.

  • Torque:
  • 15 N*m{ 148 kgf*cm, 11 ft.*lbf}
  • NOTICE:
Make sure that the sensor is oriented correctly.
If the sensor is dropped, replace it.
When installing the sensor, make sure to avoid impacts to the sensor.

Yaw Rate And Deceleration Sensor (W/ Vsc) - Installation. BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Yaw Rate And Deceleration Sensor (W/ Vsc) - Installation. BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

2. INSTALL COOLING BOX ASSEMBLY (w/ Cool Box)

()


3. INSTALL REAR CONSOLE BOX SUB-ASSEMBLY (w/o Cool Box)

()


4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
  • NOTICE:
  • When disconnecting the cable, some systems need to be initialized after the cable is reconnected ().
5. PERFORM YAW RATE SENSOR ZERO POINT CALIBRATION

Perform the yaw rate sensor zero point calibration ().

6. CHECK YAW RATE SENSOR SIGNAL

Check the yaw rate sensor signal ().