Dtc 13 Evaporator Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
INSPECT NO. 1 COOLER THERMISTOR
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - NO. 1 COOLER THERMISTOR)
DTC 13 Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator which is then used in air conditioning control. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This thermistor is used for frost prevention.DTC Code
| DTC Detection Condition
| Trouble Area
|
13
| An open or short in evaporator temperature sensor circuit
| - No. 1 cooler thermistor
- Air conditioning amplifier assembly
- Harness or connector
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |
Remove the air conditioning amplifier assembly with its connectors still connected (Toyota Fortuner RM000001K3A018X.html).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Condition
| Specified Condition
|
A37-1 (TE) - A37-14 (SG-4)
| - Ignition switch ON
- Evaporator temperature 0°C (32°F)
| 2.0 to 2.4 V
|
- Ignition switch ON
- Evaporator temperature 15°C (59°F)
| 1.4 to 1.8 V
|
Text in Illustration*a
| Component with harness connected (Air Conditioning Amplifier Assembly)
|
- HINT:
- As the temperature increases, the voltage decreases.
ResultResult
| Proceed to
|
OK (When troubleshooting according to problem symptoms table.)
| A
|
OK (When troubleshooting according to DTC.)
| B
|
NG
| C
|
2.INSPECT NO. 1 COOLER THERMISTOR |
Remove the No. 1 cooler thermistor (Toyota Fortuner RM0000012JQ01KX.html).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| -10°C (14°F)
| 7.30 to 9.10 kΩ
|
-5°C (23°F)
| 5.65 to 6.95 kΩ
|
0°C (32°F)
| 4.40 to 5.35 kΩ
|
5°C (41°F)
| 3.40 to 4.15 kΩ
|
10°C (50°F)
| 2.70 to 3.25 kΩ
|
15°C (59°F)
| 2.14 to 2.58 kΩ
|
20°C (68°F)
| 1.71 to 2.05 kΩ
|
25°C (77°F)
| 1.38 to 1.64 kΩ
|
30°C (86°F)
| 1.11 to 1.32 kΩ
|
Text in Illustration*a
| Resistance (kΩ)
|
*b
| Temperature
|
- NOTICE:
- Even slightly touching the No. 1 cooler thermistor may change the resistance value. Be sure to hold the connector of the No. 1 cooler thermistor.
- When measuring the resistance, the No. 1 cooler thermistor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (Refer to the graph).
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - NO. 1 COOLER THERMISTOR) |
Disconnect the A37 air conditioning amplifier assembly connector.
Disconnect the A19 No. 1 cooler thermistor connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
A37-1 (TE) - A19-1
| Always
| Below 1 Ω
|
A37-14 (SG-4) - A19-2
|
A37-1 (TE) - Body ground
| Always
| 10 kΩ or higher
|
A37-14 (SG-4) - Body ground
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|