Dtc 13 Evaporator Temperature Sensor Circuit


DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (TE VOLTAGE)

INSPECT NO. 1 COOLER THERMISTOR (A/C THERMISTOR)

CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)

DTC 13 Evaporator Temperature Sensor Circuit


DESCRIPTION

The No. 1 cooler thermistor (A/C thermistor) is installed on the evaporator in the A/C unit. It detects the temperature of the cooled air that has passed through the evaporator which is then used in air conditioning control. The resistance of the No. 1 cooler thermistor (A/C thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This thermistor is used for frost prevention.

DTC Code
Detection Item
Trouble Area
13
Open or short in evaporator temperature sensor circuit
  1. No. 1 cooler thermistor (A/C thermistor)
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit


INSPECTION PROCEDURE

1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (TE VOLTAGE)


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit
  1. Remove the air conditioning amplifier with its connectors still connected.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A15-1 (TE) - A15-14 (SG-4)
    Ignition switch ON
    Evaporator temperature: 0°C (32°F)
    2.0 to 2.4 V
    Ignition switch ON
    Evaporator temperature: 15°C (59°F)
    1.4 to 1.8 V
    HINT:
    As the temperature increases, the voltage decreases.
    Result
    Result
    Proceed to
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    A
    OK (Checking from the DTC)
    B
    NG
    C


B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Toyota Fortuner RM0000012KH002X.html)

C
Go to step 2
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Toyota Fortuner RM000003S6F002X.html)

2.INSPECT NO. 1 COOLER THERMISTOR (A/C THERMISTOR)


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit
  1. Remove the thermistor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ
    NOTICE:
    1. Even slightly touching the thermistor may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring the resistance, the thermistor temperature must be the same as the ambient temperature.
    HINT:
    As the temperature increases, the resistance decreases (Refer to the graph).


NG
REPLACE NO. 1 COOLER THERMISTOR (A/C THERMISTOR)
OK


3.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit
  1. Disconnect the A19 thermistor connector.

  1. Disconnect the A15 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A15-1 (TE) - A19-1
    Always
    Below 1 Ω
    A15-14 (SG-4) - A19-2
    A15-1 (TE) - Body ground
    Always
    10 kΩ or higher
    A15-14 (SG-4) - Body ground


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Toyota Fortuner RM0000012KH002X.html)