Dtc 11 Room Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT COOLER THERMISTOR (A/C ROOM TEMPERATURE SENSOR)
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (TR VOLTAGE)
CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)
DTC 11 Room Temperature Sensor Circuit |
DESCRIPTION
The cooler thermistor (A/C room temperature sensor) is installed in the instrument panel to detect the room temperature and control the heater and air conditioning AUTO function. The resistance of the cooler thermistor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies voltage (5 V) to the cooler thermistor and reads voltage changes as the resistance of the cooler thermistor changes.DTC Code
| Detection Item
| Trouble Area
|
11
| Open or short in room temperature sensor circuit
| - Cooler thermistor (A/C room temperature sensor)
- Harness or connector
- Air conditioning amplifier assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT COOLER THERMISTOR (A/C ROOM TEMPERATURE SENSOR) |
Remove the cooler thermistor.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| 10°C (50°F)
| 3.00 to 3.73 kΩ
|
15°C (59°F)
| 2.45 to 2.88 kΩ
|
20°C (68°F)
| 1.95 to 2.30 kΩ
|
25°C (77°F)
| 1.60 to 1.80 kΩ
|
30°C (86°F)
| 1.28 to 1.47 kΩ
|
35°C (95°F)
| 1.00 to 1.22 kΩ
|
40°C (104°F)
| 0.80 to 1.00 kΩ
|
45°C (113°F)
| 0.65 to 0.85 kΩ
|
50°C (122°F)
| 0.50 to 0.70 kΩ
|
55°C (131°F)
| 0.44 to 0.60 kΩ
|
60°C (140°F)
| 0.36 to 0.50 kΩ
|
- NOTICE:
- Even slightly touching the thermistor may change the resistance value. Be sure to hold the connector of the thermistor.
- When measuring the resistance, the thermistor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (Refer to the graph).
2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (TR VOLTAGE) |
Remove the air conditioning amplifier with its connectors still connected.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Switch Condition
| Specified Condition
|
A15-18 (TR) - A15-13 (SG-3)
| Ignition switch ON Cabin temperature: 25°C (77°F)
| 1.8 to 2.2 V
|
Ignition switch ON Cabin temperature: 40°C (104°F)
| 1.2 to 1.6 V
|
- HINT:
- As the temperature increases, the voltage decreases.
ResultResult
| Proceed to
|
OK (Checking from the PROBLEM SYMPTOMS TABLE)
| A
|
OK (Checking from the DTC)
| B
|
NG
| C
|
3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the A17 thermistor connector.
Disconnect the A15 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
A15-18 (TR) - A17-2
| Always
| Below 1 Ω
|
A15-13 (SG-3) - A17-1
|
A15-18 (TR) - Body ground
| Always
| 10 kΩ or higher
|
A15-13 (SG-3) - Body ground
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|