Dtc P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve Slu)
DESCRIPTION
MONITOR DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
INSPECT SHIFT SOLENOID VALVE SLU
DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) |
DESCRIPTION
The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).Duty Ratio (%) = A / (A + B) x 100DTC Code
| DTC Detection Condition
| Trouble Area
|
P2759
| Open or short is detected in shift solenoid valve SLU circuit for 1 sec. or more while driving (1 trip detection logic)
| - Open or short in shift solenoid valve SLU circuit
- Shift solenoid valve SLU
- ECM
|
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store this DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU) |
Disconnect the E1 wire connector.
Measure the resistance of the wire connector.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
13 (SLU+) - 5 (SLU-)
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
13 (SLU+) - Body ground
| Always
| 1 MΩ or higher
|
5 (SLU-) - Body ground
| Always
| 1 MΩ or higher
|
2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Disconnect the E16 ECM connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
E16-15 (SLU+) - E16-14 (SLU-)
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
E16-15 (SLU+) - Body ground
| Always
| 1 MΩ or higher
|
E16-14 (SLU-) - Body ground
| Always
| 1 MΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.INSPECT SHIFT SOLENOID VALVE SLU |
Remove the shift solenoid valve SLU.
Measure the resistance of the solenoid valve.
- Standard resistance:
- 5.0 to 5.6 Ω at 20°C (68°F)
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
- OK:
- Valve moves and makes operating noise.
- HINT:
- Reference: Inspect using an oscilloscope.
- Check the waveform of the ECM connector.
- OK:
- Refer to illustration.
Item
| Content
|
Tester Connection
| E16-15 (SLU+) - E16-14 (SLU-)
|
Tool Setting
| 5 V/DIV., 1 msec./DIV.
|
Condition
| 4th (lock-up) or 5th (lock-up) gear
|
| REPLACE SHIFT SOLENOID VALVE SLU |
|
|
OK |
|
|
|
REPAIR OR REPLACE TRANSMISSION WIRE |
|