Sfi System - Ecm Power Source Circuit(2007/12 - 2009/01)

Brand:

Toyota

Model Name:

Camry ACV40 GSV40

Manual:

Repair Manual

Section:

2Gr-Fe Engine Control System

Title:

Sfi System

  1. Description

  2. Wiring diagram

  3. Inspection procedure

  4. Check harness and connector (ecm - body ground)

  5. Check engine room junction block (efi relay voltage)

  6. Inspect efi main fuse

  7. Check harness and connector (engine room junction block - battery)

  8. Inspect engine room junction block (efi relay)

  9. Inspect efi no. 2 fuse

  10. Check harness and connector (ecm - engine room junction block)

  11. Inspect ecm (igsw voltage)

  12. Inspect ignition relay no. 2

  13. Check harness and connector (ig2 relay - body ground)

  14. Inspect ignition switch assembly

  15. Check harness and connector (ecm - body ground)

SFI SYSTEM > ECM Power Source Circuit


​

DESCRIPTION

When the ignition switch is turned to the ON position, the battery voltage is applied to terminal IGSW of the ECM. The ECM MREL output signal causes a current to flow to the coil, closing the contacts of the EFI relay and supplying power to terminal +B of the ECM.
If the ignition switch is turned off, the ECM holds the EFI relay ON for a maximum of 2 seconds to allow for the initial setting of the throttle valve.
When the ignition switch is turned to the ON position, voltage from the ECM's MREL terminal is applied to the engine room junction block (EFI relay). This causes the contacts of the engine room junction block (EFI relay) to close, which supplies power to terminal +B or +B2 of the ECM.

WIRING DIAGRAM


Sfi System - Ecm Power Source Circuit(2006/01 - 2007/12) Camry


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
  1. Disconnect the C58 (RHD) or C55 (LHD) ECM connector. Camry
  2. Disconnect the C58 (RHD) or C55 (LHD) ECM connector.

  1. Measure the resistance between the terminals.

    Standard resistance:
    RHD:
    Tester Connection
    Specified Condition
    E1 (C58-81) - Body ground
    Below 1 Ω
    LHD:
    Tester Connection
    Specified Condition
    E1 (C55-81) - Body ground
    Below 1 Ω
  1. Reconnect the ECM connector.



NGnext
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
next down

2.CHECK ENGINE ROOM JUNCTION BLOCK (EFI RELAY VOLTAGE)
  1. Remove the engine room junction block from the engine room R/B. Camry
  2. Remove the engine room junction block from the engine room R/B.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage between the terminals.

    Standard voltage:
    Tester Connection
    Specified Condition
    1E-6 - Body ground
    9 to 14 V


OKnext
Go to step 5
NG
next down

3.INSPECT EFI MAIN FUSE
  1. Remove the EFI MAIN fuse from the engine room R/B. Camry
  2. Remove the EFI MAIN fuse from the engine room R/B.

  1. Measure the EFI MAIN fuse resistance.

    Standard resistance:
    Below 1 Ω
  1. Reinstall the EFI MAIN fuse.



NGnext
REPLACE EFI MAIN FUSE
OK
next down


4.CHECK HARNESS AND CONNECTOR (ENGINE ROOM JUNCTION BLOCK - BATTERY)
  1. Disconnect the negative battery terminal. Camry
  2. Disconnect the negative battery terminal.

  1. Disconnect the positive battery terminal.

  1. Remove the engine room junction block from the engine room R/B.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Check for open:
    Tester Connection
    Specified Condition
    1G-1 - Positive battery terminal
    Below 1 Ω
    Check for short:
    Tester Connection
    Specified Condition
    1G-1 or Positive battery terminal - Body ground
    10 kΩ or higher
  1. Reinstall the engine room junction block.

  1. Reconnect the positive battery terminal.

  1. Reconnect the negative battery terminal.



NGnext
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
next down
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

5.INSPECT ENGINE ROOM JUNCTION BLOCK (EFI RELAY)
  1. Remove the engine room junction block from the engine room R/B. Camry
  2. Remove the engine room junction block from the engine room R/B.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    1E-6 - 1E-12
    10 kΩ or higher
    1E-6 - 1E-12
    Below 1 Ω
    (Apply battery voltage between terminals 1E-9 and 1E-11)
  1. Reinstall the engine room junction block.



NGnext
REPLACE ENGINE ROOM JUNCTION BLOCK
OK
next down

6.INSPECT EFI NO. 2 FUSE
  1. Remove the EFI No. 2 fuse from the engine room R/B. Camry
  2. Remove the EFI No. 2 fuse from the engine room R/B.

  1. Measure the EFI No. 2 fuse resistance.

    Standard resistance:
    Below 1 Ω
  1. Reinstall the EFI No. 2 fuse.



NGnext
REPLACE EFI NO. 2 FUSE
OK
next down

7.CHECK HARNESS AND CONNECTOR (ECM - ENGINE ROOM JUNCTION BLOCK)
  1. Disconnect the A24 (RHD) or A55 (LHD) ECM connector. Camry
  2. Disconnect the A24 (RHD) or A55 (LHD) ECM connector.

  1. Remove the engine room junction block from the engine room R/B.

  1. Measure the resistance between the terminals.

    Standard resistance (Check for open):
    RHD:
    Tester Connection
    Specified Condition
    1E-6 - +B (A24-2)
    Below 1 Ω
    1E-6 - +B2 (A24-1)
    Below 1 Ω
    LHD:
    Tester Connection
    Specified Condition
    1E-6 - +B (A55-2)
    Below 1 Ω
    1E-6 - +B2 (A55-1)
    Below 1 Ω

    Standard resistance (Check for open):
    RHD:
    Tester Connection
    Specified Condition
    1E-6 or +B (A24-2) - Body ground
    10 kΩ or higher
    1E-6 or +B2 (A24-1) - Body ground
    10 kΩ or higher
    LHD:
    Tester Connection
    Specified Condition
    1E-6 or +B (A55-2) - Body ground
    10 kΩ or higher
    1E-6 or +B2 (A55-1) - Body ground
    10 kΩ or higher
  1. Reinstall the engine room junction block.

  1. Reconnect the ECM connector.



NGnext
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
next down

8.INSPECT ECM (IGSW VOLTAGE)
  1. Disconnect the A24 (RHD) or A55 (LHD) ECM connector. Camry
  2. Disconnect the A24 (RHD) or A55 (LHD) ECM connector.

  1. Measure the voltage between the terminals.

    Standard voltage:
    RHD:
    Tester Connection
    Specified Condition
    IGSW (A24-28) - Body ground
    9 to 14 V
    LHD:
    Tester Connection
    Specified Condition
    IGSW (A55-28) - Body ground
    9 to 14 V
  1. Reconnect the ECM connector.



OKnext
Go to step 12
NG
next down

9.INSPECT IGNITION RELAY NO. 2
  1. Remove the IG2 relay from the engine room R/B. Camry
  2. Remove the IG2 relay from the engine room R/B.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω
    (Apply battery voltage between terminals 1 and 2)
  1. Reinstall the IG2 relay.



NGnext
REPLACE IGNITION RELAY NO. 2
OK
next down

10.CHECK HARNESS AND CONNECTOR (IG2 RELAY - BODY GROUND)
  1. Remove the IG2 relay from the engine room R/B. Camry
  2. Remove the IG2 relay from the engine room R/B.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    IG2 relay terminal 2 - Body ground
    Below 1 Ω
  1. Reinstall the IG2 relay.

    Result:
    Result
    Proceed to
    OK
    A
    NG
    B


Bnext
REPAIR OR REPLACE HARNESS OR CONNECTOR
A
next down

11.INSPECT IGNITION SWITCH ASSEMBLY
  1. Disconnect the E23 ignition switch connector. Camry
  2. Disconnect the E23 ignition switch connector.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Ignition Switch Position
    Specified Condition
    All terminals
    LOCK
    10 kΩ or higher
    2 - 4
    ACC
    Below 1 Ω
    1 - 2 - 4, 5 - 6
    ON
    1 - 3 - 4, 5 - 6 - 7
    START
  1. Reconnect the ignition switch connector.



NGnext
REPLACE IGNITION SWITCH ASSEMBLY
OK
next down
REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - BATTERY)

12.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
  1. Disconnect the A24 (RHD) or A55 (LHD) ECM connector. Camry
  2. Disconnect the A24 (RHD) or A55 (LHD) ECM connector.

  1. Measure the resistance between the terminals.

    Standard resistance:
    RHD:
    Tester Connection
    Specified Condition
    MREL (A24-24) - Body ground
    Below 1 Ω
    LHD:
    Tester Connection
    Specified Condition
    MREL (A55-24) - Body ground
    Below 1 Ω
  1. Reconnect the ECM connector.



NGnext
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
next down
REPLACE ECM (Click here)