Toyota
Camry ACV40 GSV40
Repair Manual
2Gr-Fe Engine Control System
Sfi System
DTC P0100 Mass or Volume Air Flow Circuit
DTC P0102 Mass or Volume Air Flow Circuit Low Input
DTC P0103 Mass or Volume Air Flow Circuit High Input
DESCRIPTION
The Mass Air Flow (MAF) meter is a sensor that measures the amount of air flowing through the valve.The ECM uses this information to determine the fuel injection time and to prove appropriate air-fuel ratio.
Inside the MAF meter, there is a heated platinum wire which is exposed to the flow of intake air.
By applying a specific electrical current to the wire, the ECM heats it to a given temperature. The flow of incoming air cools both the wire and an internal thermistor, affecting their resistance. To maintain a constant current value, the ECM varies the voltage applied to these components in the MAF meter. The voltage level is proportional to the airflow through the sensor, and the ECM uses it to calculate the intake air volume.
The circuit is constructed so that the platinum hot wire and the temperature sensor provide a bridge circuit, and the power transistor is controlled so that the potentials of A and B remain equal to maintain the predetermined temperature.
- HINT:
- When any of these DTCs are set, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine RPM and throttle valve position. Fail-safe mode continues until a pass condition is detected.

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | Open or short in Mass Air Flow (MAF) meter circuit for 3 seconds |
|
| P0102 | Open in Mass Air Flow (MAF) meter circuit for 3 seconds |
|
| P0103 | Short in Mass Air Flow (MAF) meter circuit for 3 seconds |
|
- HINT:
- When any of these DTCs are set, check the air-flow rate by entering the following menus on the intelligent tester: Powertrain / Engine / Data List / MAF.
| Mass Air Flow Rate (gm/s) | Malfunctions |
| Approximately 0.0 |
|
| 271.0 or more | Open in EVG circuit |
WIRING DIAGRAM

INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction (Click here).
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Enter the following menus: Powertrain / Engine / Data List / MAF.
Read the values displayed on the tester.
- Result:
Mass Air Flow Rate (gm/s) Proceed to 0.0 A 271.0 or more B Between 1.0 and 270.0 (*1) C
| Go to step 8 | |||
| CHECK FOR INTERMITTENT PROBLEMS | |||
| A | |
![]() |

Disconnect the C2 mass air flow (MAF) meter connector.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection Specified Condition +B (C2-3) - Body ground 9 to 14 V
Reconnect the MAF meter connector.
| Go to step 5 | |||
| OK | |
![]() |

Inspect the output voltage.
Apply battery voltage across terminals +B and E2G.
Connect the positive (+) tester probe to terminal VG, and negative (-) tester probe to terminal E2G.
Measure the voltage between the terminals.
- Standard voltage:
Tester Connection Specified Condition 5 (VG) - 4 (E2G) 0.2 to 4.9 V
| REPLACE MASS AIR FLOW METER (Click here) | |||
| OK | |
![]() |

Disconnect the C2 MAF meter connector.
Disconnect the C58 (RHD) or C55 (LHD) ECM connector.
Measure the resistance between the terminals.
- Standard resistance (Check for open):
- RHD:
Tester Connection Specified Condition VG (C58-72) - VG (C2-5) Below 1 Ω E2G (C58-73) - E2G (C2-4) Below 1 Ω - LHD:
Tester Connection Specified Condition VG (C55-72) - VG (C2-5) Below 1 Ω E2G (C55-73) - E2G (C2-4) Below 1 Ω
- Standard resistance (Check for short):
- RHD:
Tester Connection Specified Condition VG (C58-72) or VG (C2-5) - Body ground 10 kΩ or higher E2G (C58-73) or E2G (C2-4) - Body ground 10 kΩ or higher - LHD:
Tester Connection Specified Condition VG (C55-72) or VG (C2-5) - Body ground 10 kΩ or higher E2G (C55-73) or E2G (C2-4) - Body ground 10 kΩ or higher
Reconnect the MAF meter connector.
Reconnect the ECM connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |||
| OK | |
![]() | |
| REPLACE ECM | |

Remove the EFI No. 3 fuse from the engine room R/B.
Measure the EFI No. 3 fuse resistance.
- Standard resistance:
- Below 1 Ω
Reinstall the EFI No. 3 fuse.
| REPLACE EFI NO. 3 FUSE | |||
| OK | |
![]() |

Disconnect the C2 MAF meter connector.
Remove the engine room junction block from the engine room R/B.
Measure the resistance between the terminals.
- Standard resistance:
- Check for open:
Tester Connection Specified Condition +B (C2-3) - 1E-6 (Engine room R/B) Below 1 Ω - Check for short:
Tester Connection Specified Condition +B (C2-3) or 1E-6 (Engine room R/B) - Body ground 10 kΩ or higher
Reinstall the engine room junction block.
Reconnect the C2 MAF meter connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |||
| OK | |
![]() |

Remove the engine room junction block from the engine room R/B.
Inspect the EFI relay.
Measure the EFI relay resistance.
- Standard resistance:
Tester Connection Specified Condition 1E-12 - 1E-6 10 kΩ or higher 1E-12 - 1E-6 Bellow 1 Ω
(Apply battery voltage between terminals 1E-9 and 1E-10)
Reinstall the engine room junction block.
| REPLACE ENGINE ROOM JUNCTION BLOCK | |||
| OK | |
![]() | |
| CHECK ECM POWER SOURCE CIRCUIT | |

Disconnect the C2 MAF meter connector.
Measure the resistance between the terminals.
- Standard resistance:
Tester Connection Specified Condition E2G (C2-4) - Body ground Below 1 Ω
Reconnect the MAF meter connector.
| REPLACE MASS AIR FLOW METER (Click here) | |||
| NG | |
![]() |

Disconnect the C2 MAF meter connector.
Disconnect the C58 (RHD) or C55 (LHD) ECM connector.
Measure the resistance between the terminals.
- Standard resistance (Check for open):
- RHD:
Tester Connection Specified Condition VG (C58-72) - VG (C2-5) Below 1 Ω E2G (C58-73) - E2G (C2-4) Below 1 Ω - LHD:
Tester Connection Specified Condition VG (C55-72) - VG (C2-5) Below 1 Ω E2G (C55-73) - E2G (C2-4) Below 1 Ω
- Standard resistance (Check for short):
- RHD:
Tester Connection Specified Condition VG (C58-72) or VG (C2-5) - Body ground 10 kΩ or higher E2G (C58-73) or E2G (C2-4) - Body ground 10 kΩ or higher - LHD:
Tester Connection Specified Condition VG (C55-72) or VG (C2-5) - Body ground 10 kΩ or higher E2G (C55-73) or E2G (C2-4) - Body ground 10 kΩ or higher
Reconnect the MAF meter connector.
Reconnect the ECM connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |||
| OK | |
![]() | |
| REPLACE ECM (Click here) | |