Vehicle Interior. Yaris. Ncp93, 131
Heating Air Conditioning. Yaris. Ncp93, 131
Air Conditioning System (For Hatchback) -- Check Mode Procedure |
REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC) |
![]() |
Turn the ignition switch to ON.
Check that A/C switch indicator is turned on when the following conditions are met.
*: If the ambient temperature does not meet condition, do not perform this check.Measurement Condition Item Condition A/C Switch ON A/C driving time 15 minutes or more Ambient temperature* 0 to 49°C (32 to 120°F) Engine coolant temperature 45°C (113°F) or more - HINT:
- If the amount of refrigerant in the system is insufficient, air conditioning system operation stops after 11 minutes in order to prevent compressor burnout, and the A/C switch indicator light turns off.
Connect the Techstream to the DLC3.
Check for DTC B14B8.
Result Result Amount of Refrigerant Corrective Action DTC B14B8 is output Empty or nearly empty Check for gas leakage using halogen leak detector, and repair if necessary (YARIS_NCP93 RM0000026BV04GX.html) DTC B14B8 is not output Correct or insufficient Perform the refrigerant shortage check using the Techstream
REFRIGERANT SHORTAGE CHECK USING THE TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
According to the display on the Techstream, perform the refrigerant shortage check when the following conditions are met.
*: If the ambient temperature does not meet condition, do not perform this check.Measurement Condition Item Condition A/C Switch ON Ambient temperature* 0 to 49°C (32 to 120°F) R/F Switch Recirculation (Ambient temperature is 30°C (86°F) or less) Fresh (Ambient temperature is 31°C (87°F) or more) Blower Speed HI Temperature Setting MAX HOT - HINT:
- Refer to the Techstream operator's manual for further details.
- The message "The gas volume is insufficient" is shown on the Techstream screen and air conditioning system is stopped if the amount of refrigerant is insufficient in the cycle.
- The refrigerant shortage check using the Techstream does not output a DTC.
Result Result Amount of Refrigerant Corrective Action The gas volume is insufficient Insufficient or leakage - Check for gas leakage using halogen leak detector, and repair if necessary
- Evacuate air and then charge appropriate volume of new refrigerant
The gas volume is normal Correct -