Fuel Injector (For Sedan) -- Inspection |
1. INSPECT FUEL INJECTOR ASSEMBLY |
![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
- 11.6 to 12.4 Ω at 20°C (68°F)
Check the operation.
- CAUTION:
- Perform the inspection in a well-ventilated area.
- Do not perform the inspection near any naked flames.
Connect SST (fuel tube connector) to SST (hose), then connect them to the fuel pipe (vehicle side).
- SST
- 09268-31013(09268-41110,90467-13001,95336-08070,09268-41310,09268-41500)
Install the O-ring onto the fuel injector assembly.
Connect SST (adaptor and hose) to the injector assembly, and hold the injector assembly and union with SST (clamp).
- SST
- 09268-31013(09268-41110,90467-13001,95336-08070,09268-41310,09268-41500)
Set the injector assembly in a graduated cylinder.
- CAUTION:
- Install a suitable vinyl tube onto the injector assembly to prevent gasoline splashes.
Operate the fuel pump (YARIS_NCP93 RM000001EF100YX_01_0001.html ).
Connect SST (wire) to the injector assembly and the battery for 15 seconds, and measure the injection volume with the graduated cylinder. Test each injector 2 or 3 times.
- SST
- 09842-30080
- Injection volume:
- 47 to 58 cm3 (2.9 to 3.5 cu in.) per 15 seconds
- Difference between each injector:
- 11 cm3 (0.6 cu in.) or less
- NOTICE:
- Always do the switching at the battery side.
Check the leakage.
In the condition above, disconnect the test probes of SST (wire) from the battery and check the injector for fuel leakage.
- Fuel drop:
- 1 drop or less every 12 minutes
![]() |