Engine Hybrid System. Yaris. Ncp93, 131
1Nz-Fe Engine Control. Yaris. Ncp93, 131
Integration Relay (For Sedan) -- Inspection |
1. INSPECT INTEGRATION NO.1 RELAY |
![]() |
Inspect the EFI fuse.
Disconnect the fuse.
Text in Illustration *1 Fuse Side *2 EFI fuse Measure the resistance of the fuse.
- Standard Resistance:
Tester Connection Condition Specified Condition EFI fuse Always Below 1 Ω
Inspect the EFI relay.
Measure the resistance according to the value(s) in the table below.
Text in Illustration *1 Component without harness connected
(Integration Relay)- Standard Resistance:
Tester Connection Condition Specified Condition C1 - A4 Battery voltage not applied 10 kΩ or higher Battery voltage applied to terminals A2 and A3 Below 1 Ω C1 - A1 Always Below 1 Ω
- NOTICE:
- While using the battery for the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
![]() |
Inspect the FAN NO.1 relay.
Measure the resistance according to the value(s) in the table below.
Text in Illustration *1 Component without harness connected
(Integration Relay)- Standard Resistance:
Tester Connection Condition Resistance B5 - B8 Battery voltage not applied 10 kΩ or higher Battery voltage applied to terminals B6 and B7 Below 1 Ω
- NOTICE:
- While using the battery for the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
![]() |
Inspect the AM2 fuse.
Disconnect the fuse.
Text in Illustration *1 Fuse Side *2 AM2 fuse Measure the resistance of the fuse.
- Standard Resistance:
Tester Connection Condition Specified Condition AM2 fuse Always Below 1 Ω
![]() |
Inspect the IG2 relay.
Measure the resistance according to the value(s) in the table below.
Text in Illustration *1 Component without harness connected
(Integration Relay)- Standard Resistance:
Tester Connection Condition Resistance C1 - B4 Battery voltage not applied 10 kΩ or higher Battery voltage applied to terminals B2 and B3 Below 1 Ω C1 - B1 Always Below 1 Ω
![]() |
Inspect the horn relay.
Remove the horn fuse.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection Specified Condition A8 - T6 10 kΩ or higher Below 1 Ω
(Battery voltage applied to terminals A7 and T6)
![]() |