Height Control Sensor -- Inspection |
1. INSPECT REAR HEIGHT CONTROL SENSOR |
Check the rear height control sensor.
Text in Illustration *a Component without harness connected
(Rear Height Control Sensor)*b Min. Low *c Normal *d Max. High 45° 45° Connect 3 dry cell batteries of 1.5 V in series.
Connect the positive (+) end of the batteries to terminal 1 (SHB) of the height control sensor and the negative (-) end of the batteries to terminal 3 (SHG). While slowly moving the sensor link up and down, measure the voltage between terminal 2 (SHRR) and terminal 3 (SHG).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for RHD Tester Connection Sensor Condition Specified Condition 3 (SHG) - 2 (SHRR) High (45°) 4.4 to 4.6 V Normal (0°) 2.3 to 2.6 V Low (-45°) 0.4 to 0.6 V for LHD Tester Connection Sensor Condition Specified Condition 3 (SHG) - 2 (SHRL) High (45°) 4.4 to 4.6 V Normal (0°) 2.3 to 2.6 V Low (-45°) 0.4 to 0.6 V
- NOTICE:
- Do not apply higher than 6 V.