Air Conditioning System (For Manual Air Conditioning System) -- Data List / Active Test |
DATA LIST |
- HINT:
- Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- NOTICE:
- In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus:
- Body / Air Conditioner / Data List.
- Powertrain / Engine and ECT / Data List.
- Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
Air Conditioner Tester Display Measurement Item/Range Normal Condition Diagnostic Note Ambient Temp Sensor Cooler thermistor (ambient temperature sensor) /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).Adjusted Ambient Temp Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)Adjusted ambient temperature displayed - Evaporator Fin Thermistor No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)Actual evaporator temperature displayed Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).Evaporator Target Temp Target evaporator temperature /
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)Target evaporator temperature displayed - Engine Coolant Temp Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)Actual engine coolant temperature displayed - Blower Motor Speed Level Blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31 Increases in range from 0 to 31 as blower with fan motor sub-assembly speed increases - Regulator Pressure Sensor Refrigerant pressure sensor /
Min.: -0.4566 MPa
Max.: 3.2943 MPaActual refrigerant pressure displayed - Evap Temp Sens (Rear)*1 Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.25°C (138.65°F)Actual rear evaporator temperature displayed - Blower Motor Level (Rear)*1 Rear blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31 Increases in range from 0 to 31 as rear blower with fan motor sub-assembly speed increases - Air Outlet Servo Pulse (R)*1 Rear air outlet servo motor target pulse / Min.: 0, Max.: 255 83 (pulse): FACE
41 (pulse): B/L
7 (pulse): FOOT- Air Outlet Servo Actual Pls (R)*1 Rear mode damper servo sub-assembly actual pulse / Min.: 0, Max.: 255 83 (pulse): FACE
41 (pulse): B/L
7 (pulse): FOOT- Air Mix Servo Targ Pulse (R)*1 Rear air mix damper servo sub-assembly target pulse / Min.: 0, Max.: 255 9 (pulse): MAX COOL
54 (pulse): MAX HOT- Air Mix Servo Actual Pulse (R)*1 Rear air mix damper servo sub-assembly actual pulse / Min.: 0, Max.: 255 9 (pulse): MAX COOL
54 (pulse): MAX HOT- Air Mix Servo Targ Pulse (D) Damper servo sub-assembly (air mix damper servo) target / Min.: 0, Max.: 255 112 or 127 (pulse): MAX COOL
21 or 31 (pulse): MAX HOT- Air Mix Servo Actual Pulse (D) Damper servo sub-assembly (air mix damper servo) actual pulse / Min.: 0, Max.: 255 112 or 127 (pulse): MAX COOL
21 or 31 (pulse): MAX HOT- Air Outlet Servo Pulse (D) Damper servo sub-assembly (mode damper servo) / Min.: 0, Max.: 255 15 (pulse): FACE
41 (pulse): B/L
65 or 73 (pulse): FOOT
83 or 95 (pulse): F/D
113 (pulse): DEF- Air Outlet Servo Actu Pulse (D) Damper servo sub-assembly (mode damper servo) / Min.: 0, Max.: 255 15 (pulse): FACE
41 (pulse): B/L
65 or 73 (pulse): FOOT
83 or 95 (pulse): F/D
113 (pulse): DEF- Air Inlet Damper Targ Pulse Recirculation damper servo sub-assembly target pulse / Min.: 0, Max.: 255 7 (pulse): Recirculation
28 (pulse): Fresh- Air Inlet Damper Actual Pulse Recirculation damper servo sub-assembly actual pulse / Min.: 0, Max.: 255 7 (pulse): Recirculation
28 (pulse): Fresh- Electric Heater Count*3 Maximum electric heater operation level / Min.: 0, Max.: 3 Maximum possible operation of electric heater displayed - Electric Heater Active Level*3 Number of electric heaters operating / Min.: 0, Max.: 3 - - IDLE UP/PWR HEAT Switch*2 Idle up switch or heater switch assembly / ON or OFF ON: Idle up switch or heater switch assembly on
OFF: Idle up switch and heater switch assembly off- Number of Trouble Codes Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs displayed - - *1: w/ Rear Air Conditioning System
- *2: w/ Idle Up Switch or Viscous Heater
- *3: w/ PTC Heater
Engine and ECT Tester Display Measurement Item/Range Normal Condition Diagnostic Note A/C Signal A/C signal / ON or OFF ON: A/C switch on
OFF: A/C switch off- - *1: w/ Rear Air Conditioning System
ACTIVE TEST |
- HINT:
- Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
Air Conditioner Tester Display Test Part Control Range Diagnostic Note Blower Motor Blower with fan motor sub-assembly Min.: 0, Max.: 31 - Magnetic Clutch Relay Magnet clutch relay operation ON or OFF - Defogger Relay (Rear) Rear window defogger relay operation ON or OFF - Electrical Fan*1 Motor cooling fan operation ON or OFF - Heater Active Level*3 Heater level Min.: 0, Max.: 3 - Air Mix Servo Targ Pulse (D) Damper servo sub-assembly (air mix damper servo) target pulse Min.: 0, Max.: 255 - Air Outlet Servo Pulse (D) Damper servo sub-assembly (mode damper servo) pulse Min.: 0, Max.: 255 - Air Inlet Damper Targ Pulse Recirculation damper servo sub-assembly target pulse Min.: 0, Max.: 255 - Rear Blower Motor*2 Rear blower with fan motor sub-assembly Min.: 0, Max.: 31 - Rear Air Mix Servo Targ Pulse*2 Rear air mix damper servo sub-assembly target pulse Min.: 0, Max.: 255 - Viscous Heater*4 Viscous heater operation ON or OFF - A/O Servo Pulse (Rr D)*2 Rear mode damper servo sub-assembly pulse Min.: 0, Max.: 255 - - *1: except 1KD-FTV and w/ Rear Air Conditioning System
- *2: w/ Rear Air Conditioning System
- *3: w/ PTC Heater
- *4: w/ Viscous Heater
- *1: except 1KD-FTV and w/ Rear Air Conditioning System