CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND)
CAN COMMUNICATION SYSTEM (for RHD with Entry and Start System) - ECM Communication Stop Mode |
DESCRIPTION
Detection Item | Symptom | Trouble Area |
ECM Communication Stop Mode | Either condition is met:
|
|
WIRING DIAGRAM



INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND) |
for 1GR-FE:
Disconnect the ECM connectors.
Text in Illustration *a Front view of wire harness connector
(to ECM)- - Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition C36-12 (E1) - Body ground Always Below 1 Ω C36-23 (E01) - Body ground Always Below 1 Ω C37-14 (E02) - Body ground Always Below 1 Ω C36-29 (ME01) - Body ground Always Below 1 Ω G55-3 (EC) - Body ground Always Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition G55-24 (BATT) - Body ground Always 11 to 14 V G55-22 (+B2) - Body ground Battery positive (+) voltage applied to terminal G56-36 (MREL) 11 to 14 V G55-23 (+B) - Body ground Battery positive (+) voltage applied to terminal G56-36 (MREL) 11 to 14 V
for 1KD-FTV:
Disconnect the ECM connectors.
Text in Illustration *a Front view of wire harness connector
(to ECM)- - Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition C93-1 (E1) - Body ground Always Below 1 Ω C93-12 (E01) - Body ground Always Below 1 Ω C93-13 (E02) - Body ground Always Below 1 Ω C93-8 (ME01) - Body ground Always Below 1 Ω G57-11 (EC) - Body ground Always Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition G57-23 (BATT) - Body ground Always 11 to 14 V G57-17 (+B2) - Body ground Battery positive (+) voltage applied to terminal G58-11 (MREL) 11 to 14 V G57-24 (+B) - Body ground Battery positive (+) voltage applied to terminal G58-11 (MREL) 11 to 14 V
for 1GD-FTV:
Disconnect the ECM connectors.
Text in Illustration *a Front view of wire harness connector
(to ECM)- - Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition C152-1 (E1) - Body ground Always Below 1 Ω C151-3 (E01) - Body ground Always Below 1 Ω C152-4 (E02) - Body ground Always Below 1 Ω C152-3 (ME01) - Body ground Always Below 1 Ω G185-8 (EC) - Body ground Always Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition G185-1 (BATT) - Body ground Always 11 to 14 V G185-2 (+B) - Body ground Battery positive (+) voltage applied to terminal G184-14 (MREL) 11 to 14 V G185-3 (+B2) - Body ground Battery positive (+) voltage applied to terminal G184-14 (MREL) 11 to 14 V G185-4 (+B3) - Body ground Battery positive (+) voltage applied to terminal G184-14 (MREL) 11 to 14 V
Result | Proceed to |
OK (for 1GR-FE) | A |
OK (for 1KD-FTV) | B |
OK (for 1GD-FTV) | C |
NG | D |
|
| ||||
|
| ||||
|
| ||||
A | ||
|