Park / Neutral Position Switch Inspection
INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
Park / Neutral Position Switch -- Inspection |
1. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
4 (B) - 5 (L)
| Shift lever in P or N
| Below 1 Ω
|
2 (RB) - 6 (PL)
| Shift lever in P
| Below 1 Ω
|
2 (RB) - 1 (RL)
| Shift lever in R
| Below 1 Ω
|
2 (RB) - 9 (NL)
| Shift lever in N
| Below 1 Ω
|
2 (RB) - 7 (DL)
| Shift lever in D, S, "+" or "-"
| Below 1 Ω
|
4 (B) - 5 (L)
| Shift lever not in P or N
| 10 kΩ or higher
|
2 (RB) - 6 (PL)
| Shift lever not in P
| 10 kΩ or higher
|
2 (RB) - 1 (RL)
| Shift lever not in R
| 10 kΩ or higher
|
2 (RB) - 9 (NL)
| Shift lever not in N
| 10 kΩ or higher
|
2 (RB) - 7 (DL)
| Shift lever not in D, S, "+" or "-"
| 10 kΩ or higher
|
Text in Illustration*a
| Component without harness connected (Park/Neutral Position Switch Assembly)
|
If the resistance value is not as specified, replace the park/neutral position switch assembly.