Blower Resistor (For Manual Air Conditioning System) Inspection

Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Heating Air Conditioning. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSPECT BLOWER RESISTOR

Blower Resistor (For Manual Air Conditioning System) -- Inspection



1. INSPECT BLOWER RESISTOR


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Blower Resistor (For Manual Air Conditioning System)  Inspection
  1. Check the resistance.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      Always
      1.49 to 1.67 Ω
      1 - 4
      Always
      3.12 to 3.60 Ω
      1 - 3
      Always
      0.52 to 0.60 Ω
      If the result is not as specified, replace the blower resistor.
      Text in Illustration
      *a
      Component without harness connected
      (Blower Resistor)