Vehicle Stability Control System Vsc Off Indicator Light Remains On

Brake. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Brake Control Dynamic Control Systems. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK FOR DTC

READ VALUE USING INTELLIGENT TESTER (TRC/VSC OFF MODE)

PERFORM ACTIVE TEST USING INTELLIGENT TESTER (VSC WARNING LIGHT)

INSPECT VSC OFF SWITCH

CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - VSC OFF SWITCH)

CHECK TERMINAL VOLTAGE (EXI3 TERMINAL)

CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)

VEHICLE STABILITY CONTROL SYSTEM - VSC OFF Indicator Light Remains ON


DESCRIPTION

If the skid control ECU (brake actuator assembly) stores a DTC, the VSC OFF indicator light blinks in the combination meter.
Pressing the VSC OFF switch turns off traction control and pressing and holding this switch turns off traction control and VSC. If VSC turns off, the VSC OFF indicator light will come on.
When the transfer position is L4, VSC is prohibited and the VSC OFF indicator and slip indicator lights turn on.

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Brake Control Dynamic Control Systems.Anti-Lock Brake System.Vehicle Stability Control System  Vsc Off Indicator Light Remains On


INSPECTION PROCEDURE

NOTICE:
  1. As there may be malfunctions in the transfer system related to when the transfer operates in L4, check the transfer system first (HILUX_TGN26 RM00000112G00VX.html).
  2. After replacing the brake actuator assembly, perform calibration (HILUX_TGN26 RM000000XHR073X.html).
  3. Before disconnecting the connector, make sure that there are no problems with the connection.
  4. After disconnecting the connector, make sure that the connector case and terminals are not deformed or corroded.
1.CHECK FOR DTC
  1. Check if DTCs for the VSC are output (HILUX_TGN26 RM000000XHU0AYX.html).

    Result
    Result
    Proceed to
    DTC is not output
    A
    DTC is output
    B


B
REPAIR CIRCUITS INDICATED BY OUTPUT DTCS (HILUX_TGN26 RM000000XHU0AYX.html)
A


2.READ VALUE USING INTELLIGENT TESTER (TRC/VSC OFF MODE)
  1. Turn the ignition switch off.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Chassis / ABS/VSC/TRC / Data List.

    ABS/VSC/TRC
    Tester Display
    Measurement Item / Range
    Normal Condition
    Diagnostic Note
    TRC/VSC Off Mode
    VSC OFF switch / Normal, Unknown, TRC OFF or VSC OFF
    Normal: Normal mode
    TRC OFF: TRC off mode
    VSC OFF: VSC off mode
    -
  1. Check that the mode display changes according to VSC OFF switch operation.

    OK:
    The intelligent tester display changes according to VSC OFF switch operation.


NG
Go to step 4
OK


3.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (VSC WARNING LIGHT)
  1. Turn the ignition switch off.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Chassis / ABS/VSC/TRC / Active Test.

    ABS/VSC/TRC
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    VSC Warning Light
    VSC OFF indicator light
    Indicator light ON / OFF
    Observe the combination meter.
  1. When performing the VSC Warning Light Active Test, check VSC Warning Light in the Data List.

    ABS/VSC/TRC
    Tester Display
    Measurement Item / Range
    Normal Condition
    Diagnostic Note
    VSC Warning Light
    VSC OFF indicator light / ON or OFF
    ON: VSC OFF indicator light on
    OFF: VSC OFF indicator light off
    -

Result
Result
Proceed to
Data List Display
Data List Display When Performing Active Test ON/OFF Operation
ON
Does not change between ON and OFF
A
Changes between ON and OFF
B
OFF
Does not change between ON and OFF
A
Changes between ON and OFF
B


B
Go to step 7
A

REPLACE BRAKE ACTUATOR ASSEMBLY (HILUX_TGN26 RM0000010K001MX.html)

4.INSPECT VSC OFF SWITCH
  1. Turn the ignition switch off.

  1. Remove the VSC OFF switch (HILUX_TGN26 RM000001WZ2028X.html).

  1. Inspect the VSC OFF switch (HILUX_TGN26 RM000001WZ002FX.html).



NG
REPLACE VSC OFF SWITCH (HILUX_TGN26 RM000001WZ2028X.html)
OK


5.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - VSC OFF SWITCH)
  1. Turn the ignition switch off.

  1. Disconnect the VSC OFF switch connector.

  1. Disconnect the skid control ECU (brake actuator assembly) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A36-30 (CSW) - G84-3
    Always
    Below 1 Ω
    A36-30 (CSW) - Body ground
    Always
    10 kΩ or higher
    G84-4 - Body ground
    Always
    Below 1 Ω


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK TERMINAL VOLTAGE (EXI3 TERMINAL)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Brake Control Dynamic Control Systems.Anti-Lock Brake System.Vehicle Stability Control System  Vsc Off Indicator Light Remains On
  1. Turn the ignition switch off.

  1. Disconnect the skid control ECU (brake actuator assembly) connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A36-28 (EXI3) - Body ground
    Ignition switch ON
    11 to 14 V
    Text in Illustration
    *a
    Front view of wire harness connector
    (to Skid Control ECU [Brake Actuator Assembly])


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BRAKE ACTUATOR ASSEMBLY (HILUX_TGN26 RM0000010K001MX.html)

7.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)
  1. Turn the ignition switch off.

  1. Disconnect the skid control ECU (brake actuator assembly) connector.

  1. Disconnect the G20 combination meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A36-15 (VSCW) - G20-16 (TROF)
    Always
    Below 1 Ω
    A36-15 (VSCW) - Body ground
    Always
    10 kΩ or higher


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO METER / GAUGE SYSTEM (HOW TO PROCEED WITH TROUBLESHOOTING) (HILUX_TGN26 RM000002Z4L03IX.html)