Spiral Cable Inspection

Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Supplemental Restraint Systems. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSPECT SPIRAL CABLE SUB-ASSEMBLY

Spiral Cable -- Inspection



1. INSPECT SPIRAL CABLE SUB-ASSEMBLY
  1. If there are any defects as mentioned below, replace the spiral cable with a new one:
    Scratches, cracks, dents or chips in the connector or spiral cable.



    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Supplemental Restraint Systems.Airbag System.Spiral Cable  Inspection
  1. Check the spiral cable.

    Text in Illustration
    *a
    Orange

    1. Set the spiral cable to the center position (HILUX_TGN26 RM0000010AZ00SX_02_0010.html).

    2. After setting the spiral cable to the center position, rotate the spiral cable 2.5 times counterclockwise, and measure the resistance as shown. Then rotate the spiral cable 5 times clockwise, and measure the resistance as shown.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      G52-1 - A-2
      Always
      Below 1 Ω
      G52-2 - A-1
      Always
      Below 1 Ω
      G12-6 - B-10
      Always
      Below 1 Ω
      G12-5 - B-9
      Always
      Below 1 Ω
      G12-4 - B-8
      Always
      Below 1 Ω
      G12-3 - B-7
      Always
      Below 1 Ω
      G12-2 - B-6
      Always
      Below 1 Ω
      G12-2 - C-4
      Always
      Below 1 Ω
      G12-1 - C-3
      Always
      Below 1 Ω
      G12-12 - B-5
      Always
      Below 1 Ω
      G12-11 - B-4
      Always
      Below 1 Ω
      G12-10 - B-3
      Always
      Below 1 Ω
      G12-9 - B-2
      Always
      Below 1 Ω
      G12-8 - B-1
      Always
      Below 1 Ω
      G12-8 - C-2
      Always
      Below 1 Ω
      G12-7 - C-1
      Always
      Below 1 Ω
    3. After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise. Then while rotating the spiral cable 5 times counterclockwise, measure the resistance as shown.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      G52-1 - A-2
      Always
      Below 1 Ω
      G52-2 - A-1
      Always
      Below 1 Ω
      G12-6 - B-10
      Always
      Below 1 Ω
      G12-5 - B-9
      Always
      Below 1 Ω
      G12-4 - B-8
      Always
      Below 1 Ω
      G12-3 - B-7
      Always
      Below 1 Ω
      G12-2 - B-6
      Always
      Below 1 Ω
      G12-2 - C-4
      Always
      Below 1 Ω
      G12-1 - C-3
      Always
      Below 1 Ω
      G12-12 - B-5
      Always
      Below 1 Ω
      G12-11 - B-4
      Always
      Below 1 Ω
      G12-10 - B-3
      Always
      Below 1 Ω
      G12-9 - B-2
      Always
      Below 1 Ω
      G12-8 - B-1
      Always
      Below 1 Ω
      G12-8 - C-2
      Always
      Below 1 Ω
      G12-7 - C-1
      Always
      Below 1 Ω
      NOTICE:
      As the spiral cable may break, do not rotate the spiral cable more than the specified amount.