Dtc 13 Evaporator Temperature Sensor Circuit

Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Heating Air Conditioning. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT NO. 1 COOLER THERMISTOR

CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - NO. 1 COOLER THERMISTOR)

DTC 13 Evaporator Temperature Sensor Circuit


DESCRIPTION

The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator which is then used in air conditioning control. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This thermistor is used for frost prevention.

DTC Code
DTC Detection Condition
Trouble Area
13
An open or short in evaporator temperature sensor circuit
  1. No. 1 cooler thermistor
  2. Air conditioning amplifier assembly
  3. Harness or connector

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit


INSPECTION PROCEDURE

1.INSPECT NO. 1 COOLER THERMISTOR


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit
  1. Remove the No. 1 cooler thermistor (HILUX_TGN26 RM0000012JQ02BX.html).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ
    Text in Illustration
    *a
    Resistance (kΩ)
    *b
    Temperature
    NOTICE:
    1. Even slightly touching the No. 1 cooler thermistor may change the resistance value. Be sure to hold the connector of the No. 1 cooler thermistor.
    2. When measuring the resistance, the No. 1 cooler thermistor temperature must be the same as the ambient temperature.
    HINT:
    As the temperature increases, the resistance decreases (Refer to the graph).


NG
REPLACE NO. 1 COOLER THERMISTOR (HILUX_TGN26 RM0000012JQ02BX.html)
OK


2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  13  Evaporator Temperature Sensor Circuit
  1. Remove the air conditioning amplifier assembly with its connectors still connected (HILUX_TGN26 RM000001K3A01QX.html).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    G95-1 (TE) - G95-14 (SG-4)
    1. Ignition switch ON
    2. Evaporator temperature 0°C (32°F)
    2.0 to 2.4 V
    1. Ignition switch ON
    2. Evaporator temperature 15°C (59°F)
    1.4 to 1.8 V
    Text in Illustration
    *a
    Component with harness connected
    (Air Conditioning Amplifier Assembly)
    HINT:
    As the temperature increases, the voltage decreases.
    Result
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table.)
    A
    OK (When troubleshooting according to DTC.)
    B
    NG
    C


B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (HILUX_TGN26 RM000001K3A01QX.html)

C
Go to step 3
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (HILUX_TGN26 RM0000045E301DX.html)

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - NO. 1 COOLER THERMISTOR)
  1. Disconnect the G95 air conditioning amplifier assembly connector.

  1. Disconnect the G30 No. 1 cooler thermistor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G95-1 (TE) - G30-1
    Always
    Below 1 Ω
    G95-14 (SG-4) - G30-2
    G95-1 (TE) - Body ground
    Always
    10 kΩ or higher
    G95-14 (SG-4) - Body ground


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (HILUX_TGN26 RM000001K3A01QX.html)