Dtc P0976 Shift Solenoid B Control Circuit Low (Shift Solenoid Valve S2)

Drivetrain. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
A750F Automatic Transmission Transaxle. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2)

CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

INSPECT SHIFT SOLENOID VALVE S2

DTC P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)

DTC P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In case of an open or short circuit, the ECM stops sending current to the circuit. For details, refer to the fail-safe chart (HILUX_TGN26 RM000000O8L0MKX.html).

DTC Code
DTC Detection Condition
Trouble Area
P0976
The ECM detects a short in the solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1-trip detection logic).
  1. Short in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM
P0977
The ECM detects an open in the solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1-trip detection logic).
  1. Open in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S2 is on, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S2 circuit.
When the shift solenoid valve S2 is off, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve S2 circuit (HILUX_TGN26 RM000000O8L0MKX.html).

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0976  Shift Solenoid B Control Circuit Low (Shift Solenoid Valve S2)


INSPECTION PROCEDURE


HINT:
The shift solenoid valve S2 turns ON/OFF normally when the shift lever is in D.

ECM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve S2
OFF
ON
ON
OFF
OFF
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0976  Shift Solenoid B Control Circuit Low (Shift Solenoid Valve S2)
  1. Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    15 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω
    Text in Illustration
    *a
    Component without harness connected
    (Transmission Wire)


NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0976  Shift Solenoid B Control Circuit Low (Shift Solenoid Valve S2)
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C130-10 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω
    Text in Illustration
    *a
    Rear view of wire harness connector
    (to ECM)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (HILUX_TGN26 RM000000VW202SX.html)

3.INSPECT SHIFT SOLENOID VALVE S2


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0976  Shift Solenoid B Control Circuit Low (Shift Solenoid Valve S2)
  1. Remove shift solenoid valve S2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
    20°C (68°F)
    11 to 15 Ω
  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S2 connector
    2. Battery negative (-) → Shift solenoid valve S2 body
    Valve moves and makes operating noise
Text in Illustration
*a
Component without harness connected
(Shift Solenoid Valve S2)


NG
REPLACE SHIFT SOLENOID VALVE S2 (HILUX_TGN26 RM0000013FG02KX_01_0008.html)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (HILUX_TGN26 RM0000013C1047X.html)