Dtc P0976 Shift Solenoid B Control Circuit Low (Shift Solenoid Valve S2)
Drivetrain. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
DESCRIPTION
MONITOR DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2)
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
INSPECT SHIFT SOLENOID VALVE S2
DTC P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2) |
DTC P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2) |
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2 and SR, which are controlled by the TCM. If an open or short circuit occurs in one of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In the case of an open or short circuit, the TCM stops sending current to the circuit. For details, refer to the fail-safe chart (HILUX_TGN26 RM000000O8L0MCX.html).DTC Code
| DTC Detection Condition
| Trouble Area
|
P0976
| TCM detects a short in the solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1-trip detection logic).
| - Short in shift solenoid valve S2 circuit
- Shift solenoid valve S2
- TCM
|
P0977
| TCM detects an open in the solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1-trip detection logic).
| - Open in shift solenoid valve S2 circuit
- Shift solenoid valve S2
- TCM
|
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve S2 is on, if its resistance is 8 Ω or less, the TCM determines there is a short in the shift solenoid valve S2 circuit.When shift solenoid valve S2 is off, if its resistance is 100 kΩ or higher, the TCM determines there is an open in the shift solenoid valve S2 circuit (HILUX_TGN26 RM000000O8L0MCX.html).
WIRING DIAGRAM
INSPECTION PROCEDURE
- HINT:
- Shift solenoid valve S2 is turned ON/OFF normally when the shift lever is in D.
TCM gear shift command
| 1st
| 2nd
| 3rd
| 4th
| 5th
|
Shift solenoid valve S2
| OFF
| ON
| ON
| OFF
| OFF
|
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2) |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
15 (S2) - Body ground
| 20°C (68°F)
| 11 to 15 Ω
|
Text in Illustration*a
| Component without harness connected (Transmission Wire)
|
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
C24-17 (S2) - Body ground
| 20°C (68°F)
| 11 to 15 Ω
|
Text in Illustration*a
| Rear view of wire harness connector (to TCM)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.INSPECT SHIFT SOLENOID VALVE S2 |
Remove shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
| 20°C (68°F)
| 11 to 15 Ω
|
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) → Shift solenoid valve S2 connector
- Battery negative (-) → Shift solenoid valve S2 body
| Valve moves and makes an operating noise
|
Text in Illustration*a
| Component without harness connected (Shift Solenoid Valve S2)
|