Power Source Network. Corolla. Zre142 Aze141
2Az-Fe Battery Charging. Corolla. Zre142 Aze141
Generator -- Removal |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
2. REMOVE ENGINE UNDER COVER RH |
3. REMOVE V-RIBBED BELT |
Using SST, slowly turn the V-ribbed belt tensioner clockwise.
- SST
- 09216-42010(09216-04010)
![]() |
Remove the V-ribbed belt from each pulley and slowly return the tensioner.
- NOTICE:
- Make sure that SST and other tools are set to the tensioner securely.
- When compressing the V-ribbed belt tensioner, slowly turn the tensioner.
- Be careful not to pinch your fingers between the parts.
4. REMOVE GENERATOR ASSEMBLY |
Disconnect the generator connector.
![]() |
Remove the nut and disconnect the wire harness from terminal B.
Separate the 2 wire harness clamps.
Remove the 2 bolts and generator assembly.
![]() |
Remove the bolt and wire harness clamp bracket.
![]() |