Engine Hybrid System. Corolla. Zre142 Aze141
2Az-Fe Fuel. Corolla. Zre142 Aze141
Fuel Pump -- Inspection |
1. INSPECT FUEL PUMP |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
- Standard Resistance:
Tester Connection Specified Condition 1 - 2 0.2 to 3.0 Ω at 20°C (68°F)
![]() |
Check the operation.
Apply battery voltage to both terminals. Check that the pump operates.
- NOTICE:
- These tests must be done quickly (for less than 10 seconds) to prevent the coil from burning out.
- Keep the fuel pump as far away from the battery as possible.
- Always do the switching at the battery side.