Dtc P0443 Evaporative Emission Control System Purge Control Valve Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE PURGE VSV CONTROL)
INSPECT PURGE VSV
INSPECT PURGE VSV (POWER SOURCE VOLTAGE)
CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM)
DTC P0443 Evaporative Emission Control System Purge Control Valve Circuit |
DESCRIPTION
- HINT:
- This DTC P0443 is applicable to Mexico models only.
To reduce hydrocarbon emissions, evaporated fuel from the fuel tank is routed through a charcoal canister to the intake manifold for combustion in the cylinders.The ECM changes the duty signals to the purge VSV so that the intake amount of hydrocarbon emissions is appropriate for the driving conditions (engine load, engine speed, vehicle speed, etc.) after the engine is warmed up.DTC No.
| DTC Detection Condition
| Trouble Area
|
P0443
| Terminal voltage of ECM output circuit does not correspond with drive signals from ECM to purge VSV (1-trip detection logic)
| - Open or short in purge VSV circuit
- Purge VSV
- ECM
|
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
1.PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE PURGE VSV CONTROL) |
Connect the Techstream to the DLC3.
Disconnect the vacuum hose from the purge VSV.
Start the engine.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Evap Control.
When the purge VSV is operated using the Techstream, check whether the VSV applies suction to your finger.
- OK:
Techstream Operation
| Specified Condition
|
VSV is ON
| VSV applies suction to finger
|
VSV is OFF
| VSV applies no suction to finger
|
Reconnect the vacuum hose to the purge VSV.
Inspect the purge VSV (COROLLA_ZRE142 RM0000012OE01XX.html).
3.INSPECT PURGE VSV (POWER SOURCE VOLTAGE) |
Disconnect the purge VSV connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Condition
| Specified Condition
|
B19-2 - Body ground
| Ignition switch ON
| 11 to 14 V
|
Reconnect the purge VSV connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR (PURGE VSV - ENGINE ROOM RELAY BLOCK) |
|
|
4.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM) |
Disconnect the purge VSV connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
| Condition
| Specified Condition
|
B19-1 - B31-49 (PRG)
| Always
| Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
| Condition
| Specified Condition
|
B19-1 or B31-49 (PRG) - Body ground
| Always
| 10 kΩ or higher
|
Reconnect the purge VSV connector.
Reconnect the ECM connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR (PURGE VSV - ECM) |
|
|