Rear Door Lock Inspection

Body Electrical. Camry. Acv40 Gsv40
Door Lock. Camry. Acv40 Gsv40

  1. INSPECT REAR DOOR LOCK LH ASSEMBLY

  2. INSPECT REAR DOOR LOCK RH ASSEMBLY

Rear Door Lock -- Inspection



1. INSPECT REAR DOOR LOCK LH ASSEMBLY
  1. Remove the rear door lock assembly LH.



    Camry. Acv40 Gsv40.Door Lock.Power Door Lock Control System.Rear Door Lock  Inspection
  1. Check operation of the door lock motor.

    1. Apply battery voltage and check operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock


    Camry. Acv40 Gsv40.Door Lock.Power Door Lock Control System.Rear Door Lock  Inspection
  1. Check operation of the unlock detection switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Measurement Condition
      Door Lock Condition
      Specified Condition
      6 - 9
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      10 kΩ or higher
      6 - 9
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock
      Below 1 Ω


2. INSPECT REAR DOOR LOCK RH ASSEMBLY
  1. Remove the rear door lock assembly RH.



    Camry. Acv40 Gsv40.Door Lock.Power Door Lock Control System.Rear Door Lock  Inspection
  1. Check operation of the door lock motor.

    1. Apply battery voltage and check operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock


    Camry. Acv40 Gsv40.Door Lock.Power Door Lock Control System.Rear Door Lock  Inspection
  1. Check operation of the unlock detection switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Measurement Condition
      Door Lock Condition
      Specified Condition
      6 - 9
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      10 kΩ or higher
      6 - 9
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock
      Below 1 Ω