Dtc B1411/11 Room Temperature Sensor Circuit

Air Conditioning. Camry. Acv40 Gsv40

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

READ VALUE USING INTELLIGENT TESTER

INSPECT AIR CONDITIONING AMPLIFIER

INSPECT A/C ROOM TEMPERATURE SENSOR

CHECK HARNESS AND CONNECTOR (A/C ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

DTC B1411/11 Room Temperature Sensor Circuit


DESCRIPTION

This sensor detects the cabin temperature that is used as the basis for temperature control and sends a signal to the A/C amplifier.

DTC No.
DTC Detection Condition
Trouble Area
B1411/11
Room temperature sensor circuit (Open or short)
  1. A/C room temperature sensor
  2. Harness or connector between A/C room temperature sensor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.
Dtc
  B1411/11  Room Temperature Sensor Circuit


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the display on the intelligent tester.

    Data List / Air Conditioner:
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    (Room Temp)
    Room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F)
    Actual cabin temperature is displayed
    -
    OK:
    The display is as specified in the normal condition column.

    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C


B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.INSPECT AIR CONDITIONING AMPLIFIER


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.
Dtc
  B1411/11  Room Temperature Sensor Circuit
  1. Remove the A/C amplifier with the connectors still connected.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E38-29 (TR) - E38-34 (SG-1)
    Ignition switch: ON
    at 25°C (77°F)
    1.35 to 1.75 V
    E38-29 (TR) - E38-34 (SG-1)
    Ignition switch: ON
    at 40°C (104°F)
    0.9 to 1.2 V
    HINT:
    As the temperature increases, the voltage decreases.
    Result:
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C


B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3.INSPECT A/C ROOM TEMPERATURE SENSOR


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.
Dtc
  B1411/11  Room Temperature Sensor Circuit
  1. Remove the A/C room temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E27-1 - E27-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    E27-1 - E27-2
    15°C (59°F)
    2.45 to 2.88 kΩ
    E27-1 - E27-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    E27-1 - E27-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    E27-1 - E27-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    E27-1 - E27-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    E27-1 - E27-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    E27-1 - E27-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    E27-1 - E27-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    E27-1 - E27-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    E27-1 - E27-2
    60°C (140°F)
    0.36 to 0.50 kΩ
    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.
    HINT:
    As the temperature increases, the resistance decreases (see the graph).


NG
REPLACE A/C ROOM TEMPERATURE SENSOR
OK


4.CHECK HARNESS AND CONNECTOR (A/C ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.
Dtc
  B1411/11  Room Temperature Sensor Circuit
  1. Disconnect the connector from the A/C amplifier.



    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.
Dtc
  B1411/11  Room Temperature Sensor Circuit
  1. Disconnect the connector from the A/C room temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E38-29 (TR) - E27-1
    Always
    Below 1 Ω
    E38-34 (SG-1) - E27-2
    Always
    Below 1 Ω
    E38-29 (TR) - Body ground
    Always
    10 kΩ or higher
    E38-34 (SG-1) - Body ground
    Always
    10 kΩ or higher


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER