Meter / Gauge System Entire Combination Meter Does Not Operate

Body Electrical. Camry. Acv40 Gsv40
Meter. Camry. Acv40 Gsv40

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT COMBINATION METER ASSEMBLY

METER / GAUGE SYSTEM - Entire Combination Meter does not Operate


DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU, however, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when turn the ignition switch to the ON position, the indicator will not operate.

WIRING DIAGRAM


Camry. Acv40 Gsv40.Meter.Meter / Gauge System.Meter / Gauge System  Entire Combination Meter Does Not Operate


INSPECTION PROCEDURE

1.INSPECT COMBINATION METER ASSEMBLY


    Camry. Acv40 Gsv40.Meter.Meter / Gauge System.Meter / Gauge System  Entire Combination Meter Does Not Operate
  1. Disconnect the F1 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    F1-12 (E2) - Body ground
    Always
    Below 1 Ω
    F1-24 (ES) - Body ground
    Always
    Below 1 Ω
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    F1-13 (IG+) - Body ground
    Turn the ignition switch to the ON position
    10 to 14 V
    F1-1 (B2) - Body ground
    Always
    10 to 14 V
    F1-2 (B) - Body ground
    Always
    10 to 14 V


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK