Dtc P2716 Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
DESCRIPTION
MONITOR DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT TRANSMISSION WIRE (SLT)
INSPECT SHIFT SOLENOID VALVE SLT
DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
DESCRIPTION
Refer to DTC P2714 (Link).DTC No.
| DTC Detection Condition
| Trouble Area
|
P2716
| Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
| - Open or short in shift solenoid valve SLT circuit
- Shift solenoid valve SLT
- TCM
|
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT TRANSMISSION WIRE (SLT) |
Remove the TCM from the transaxle.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Specified Condition 20°C (68°F)
|
7 (SLT-) - 12 (SLT+)
| 5.0 to 5.6 Ω
|
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- Check for short:
Tester Connection
| Specified Condition
|
7 (SLT-) - Body ground
| 10 kΩ or higher
|
12 (SLT+) - Body ground
| 10 kΩ or higher
|
2.INSPECT SHIFT SOLENOID VALVE SLT |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Specified Condition 20°C (68°F)
|
1 - 2
| 5.0 to 5.6 Ω
|
Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
| REPLACE SHIFT SOLENOID VALVE SLT |
|
|
OK |
|
|
|