Remove the 2 nuts and cover.

Disconnect the mass air flow meter connector (*1).
Disconnect the purge VSV connector (*2).
Disconnect the 2 purge VSV vacuum hoses (*3).
Disconnect the purge line hose from the clamp (*4).

Disconnect the No. 2 ventilation hose from the air cleaner hose.

Lock the No. 1 air cleaner hose clamp, and then disconnect the No. 1 air cleaner hose from the throttle body.

Remove the 2 bolts and air cleaner cap.
Remove the air cleaner filter element from the air cleaner case.

Disconnect the hose clamp.
Remove the 3 bolts and air cleaner case.

Remove the 2 bolts and air cleaner bracket.

Disconnect the 2 ECM connectors.
- NOTICE:
- After disconnecting the connector, make sure that dirt, water and other foreign matter does not contact the connecting part of the connector.
Raise the 2 levers while pushing the locks on the levers, and disconnect the 2 ECM connectors.

Remove the 3 bolts of the ECM with bracket.
Remove the ECM with bracket.

Remove the 4 screws and ECM bracket.