Brand:
Toyota
Model Name:
4Runner GRN210 215 UZN210 215
Manual:
Repair Manual
Section:
Service Specifications
Title:
2Uz-Fe Emission Control
| VSV for charcoal canister | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 42 Ω | |
| VSV for EVAP | ||
| Resistance | at 20°C (68°F) | 26 to 30 Ω |
| Heated oxygen sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity |
| Heated oxygen sensor No. 2 (Bank 1) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity |
| Heated oxygen sensor No. 2 (Bank 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity |
| Pressure sensor | ||
| Voltage | AIP-E2 | 1.0 to 2.2 V |
| Vacuum switching valve assembly | ||
| Resistance | 1-2 | 33 to 39 Ω at 20°C (68°F) |
| 1-Body ground | 10 MΩ or higher | |
| 2-Body ground | 10 MΩ or higher | |