Toyota
4Runner GRN210 215 UZN210 215
Repair Manual
1Gr-Fe Engine Control System
Sfi System
Read value of intelligent tester (engine coolant temperature)
Read value of intelligent tester (check for open in wire harness)
Read value of intelligent tester (check for short in wire harness)
DTC P0115 Engine Coolant Temperature Circuit
DTC P0117 Engine Coolant Temperature Circuit Low Input
DTC P0118 Engine Coolant Temperature Circuit High Input
DESCRIPTION
A thermistor is built into the Engine Coolant Temperature (ECT) sensor, of which the resistance value varies according to the ECT.The structure of the sensor and its connection to the ECM are the same as those of the Intake Air Temperature (IAT) sensor.
- HINT:
- When any of DTCs P0115, P0117 and P0118 are set, the ECM enters fail-safe mode. During fail-safe mode, the ECT is estimated to be 80°C (176°F) by the ECM. Fail-safe mode continues until a pass condition is detected.
| DTC No. | Proceed to | DTC Detection Conditions | Trouble Areas |
| P0115 | Step 1 | Open or short in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0117 | Step 4 | Short in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0118 | Step 2 | Open in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
- HINT:
- When any of these DTCs are set, check the ECT by selecting the following menu items on the intelligent tester: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / COOLANT TEMP.
| Temperature Displayed | Malfunctions |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |
MONITOR DESCRIPTION
The Engine Coolant Temperature (ECT) sensor is used to monitor the ECT. The ECT sensor has a thermistor with a resistance that varies according to the temperature of the engine coolant. When the coolant temperature is low, the resistance in the thermistor increases. When the temperature is high, the resistance drops.These variations in resistance are reflected in the voltage output from the sensor. The ECM monitors the sensor voltage and uses this value to calculate the ECT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a fault in the ECT sensor and sets a DTC.
- If the sensor voltage output is -40°C (-40°F) for 0.5 seconds or more, the ECM determines that there is an open in the ECT sensor circuit, and sets DTC P0118. Conversely, if the voltage output is more than 140°C (284°F) for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and sets DTC P0117.
- If the malfunction is not repaired successfully, a DTC is set 0.5 seconds after the engine is next started.
MONITOR STRATEGY
| Related DTCs | P0115: ECT sensor range check (Fluttering) P0117: ECT sensor range check (Low voltage) P0118: ECT sensor range check (High voltage) |
| Required Sensors / Components (Main) | Engine coolant temperature sensor |
| Required Sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever these DTCs are not present | None |
TYPICAL MALFUNCTION THRESHOLDS
| Engine coolant temperature sensor voltage | Less than 0.14 V or more than 4.91 V [More than 140°C (284°F), or less than -40°C (-40°F)] |
| Engine coolant temperature sensor voltage | Less than 0.14 V [More than 140°C (284°F)] |
| Engine coolant temperature sensor voltage | More than 4.91 V [Less than -40°C (-40°F)] |
COMPONENT OPERATING RANGE
| Engine coolant temperature sensor voltage | 0.14 V to 4.91 V [-40 to 140°C (-40 to 284°F)] |
WIRING DIAGRAM

INSPECTION PROCEDURE
- HINT:
- If other DTCs relating to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / COOLANT TEMP.
Read the value displayed on the tester.
- Standard:
- Between 80°C and 97°C (176°F and 207°F) with warm engine.
- Result:
Temperature Displayed Proceed to -40°C (-40°F) A 140°C (284°F) or higher B Between 80°C and 97°C (176°F and 207°F) C
- HINT:
- If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
- If there is a short circuit, the intelligent tester indicates 140°C (284°F) or higher.
| Go to step 4 | |||
| CHECK FOR INTERMITTENT PROBLEMS | |||
| A | |
![]() |

Disconnect the E2 Engine Coolant Temperature (ECT) sensor connector.
Connect terminals 1 and 2 of the ECT sensor connector on the wire harness side.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / COOLANT TEMP.
Read the value displayed on the tester.
- Standard:
- 140°C (284°F) or higher
Reconnect the ECT sensor connector.
| CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE ENGINE COOLANT TEMPERATURE SENSOR | |||
| NG | |
![]() |

Disconnect the E4 ECT sensor connector.
Connect terminals THW and E2 of the E4 ECM connector.
- HINT:
- Before checking, do visual and contact pressure checks on the ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / COOLANT TEMP.
Read the value displayed on the tester.
- Standard:
- 140°C (284°F) or higher
Reconnect the ECT sensor connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |||
| NG | |
![]() | |
| CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM | |

Disconnect the E2 ECT sensor connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / COOLANT TEMP.
Read the value displayed on the tester.
- Standard:
- -40°C (-40°F)
Reconnect the ECT sensor connector.
| REPLACE ENGINE COOLANT TEMPERATURE SENSOR | |||
| NG | |
![]() |

Disconnect the E4 ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / COOLANT TEMP.
Read the value displayed on the tester.
- Standard:
- -40°C (-40°F)
Reconnect the ECM connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |||
| NG | |
![]() | |
| REPLACE ECM | |