DTC P2419 Evaporative Emission Pressure Switching Valve Stuck ON
DTC P2420 Evaporative Emission Pressure Switching Valve Stuck OFF
DTC SUMMARY
| DTC No. | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timing | Detection Logic |
| P2419 | Vent valve stuck closed | Vacuum pump creates negative pressure through 0.02 inch orifice and EVAP system pressure measured to determine leak pressure standard. If system pressure higher than -1.06 kPa (-7.95 mmHg)* 4 seconds after vacuum pump turned ON, ECM determines that vent valve stuck closed. |
| Ignition switch OFF | 2 trip |
| P2420 | Vent valve stuck open (vent) | Vacuum pump creates negative pressure through 0.02 inch orifice and EVAP system pressure measured to determine leak pressure standard. 0.02 inch leak pressure standard is measured at the start and at the end of the leak check. If system pressure does not increase by more than 0.3 kPa (2.25 mmHg) within 10 seconds when vent valve turned ON, ECM determines that vent valve stuck closed. |
| Ignition switch OFF | 2 trip |
- HINT:
- The vent value is built into the pump module.
DESCRIPTION
The circuit description can be found in the Evaporative Emission (EVAP) system (Click here).INSPECTION PROCEDURE
Refer to the EVAP system (Click here).MONITOR DESCRIPTION
5 hours* after the ignition switch is turned OFF, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.- HINT:
- *: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned OFF, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned OFF, the monitor check starts 2.5 hours later.
| Sequence | Operations | Descriptions | Duration |
| - | ECM activation | Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak criterion (reference pressure) measurement | In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 900 seconds, ECM cancels EVAP system monitor. | 900 seconds* |
| D | Purge VSV monitor | Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak criterion (reference pressure) measurement | After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking. | 60 seconds |
| F | Final check | Atmospheric pressure measured and then monitoring result recorded by ECM. | - |

- P2419: Vent valve stuck closed
In operation B, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM using the canister pressure sensor to determine the 0.02 inch leak criterion. If the pressure exceeds -1.06 kPa (-7.95 mmHg)* 4 seconds after the leak detection pump is turned ON, the ECM interprets this as the vent valve being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).
*: The threshold varies according to the atmospheric pressure measured in operation A. The values described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.
- P2420: Vent valve stuck open (vent)
In operation C, the vent valve turns ON (closes) and the EVAP system pressure is then measured by the ECM using the canister pressure sensor to conduct an EVAP leak check. If pressure does not drop when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and sets the DTC.
MONITOR STRATEGY
| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | 2 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever these DTCs are not present | None |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or higher |
| Vehicle speed | 2.5 mph (4 km/h) or less |
| Ignition switch | OFF |
| Time after key off | 5 or 7 or 9.5 hours |
| EVAP pressure sensor malfunction (P0450, P0452, P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following are met before key off | Condition 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
Key-off monitor sequence 1 to 8
| Next sequence is run if the following condition is met | - |
| Atmospheric pressure change | Within 0.3 kPa (2.25 mmHg) in 1 second |
| Next sequence is run if the following conditions set | - |
| EVAP pressure just after reference pressure measurement start | -1 kPa (-7.5 mmHg) or lower |
| Reference pressure | -4.85 to -1.05 kPa (726 to 754 mmHg) |
| Reference pressure | Saturated |
| Next sequence is run if the following conditions set | - |
| EVAP pressure change after vent valve is ON | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following conditions set | - |
| EVAP pressure | Saturated within 900 seconds |
| Next sequence is run if the following conditions set | - |
| EVAP pressure change after purge valve is open | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following conditions set | - |
| EVAP pressure just after reference pressure measurement | -1 kPa (-7.5 mmHg) or lower |
| Reference pressure | -4.85 to -1.05 kPa (-36.38 to -7.93 mmHg) |
| Reference pressure | Saturated within 55 seconds |
| Difference between first reference pressure and second reference pressure | Less than 0.7 kPa (5.25 mmHg) |
| Next sequence is run if the following conditions set | - |
| EVAP pressure when vacuum introduction is complete | Lower than second reference pressure |
| EVAP monitor is complete if the following conditions set | - |
| Atmospheric pressure difference between sequence 1 and 8 | Within 0.3 kPa (2.25 mmHg) |
TYPICAL MALFUNCTION THRESHOLDS
- P2419: Vent valve stuck closed
"Saturated" indicates that the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) in 30 seconds.One of following conditions set - 1. EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or higher 2. Reference pressure Less than -4.85 kPa (726 mmHg) 3. Reference pressure -1.05 kPa (-7.93 mmHg) or higher 4. Reference pressure Not saturated 5. Difference between first reference pressure and second reference pressure 0.7 kPa (5.25 mmHg) or more - P2420: Vent valve stuck open (vent)
EVAP pressure change after EVAP canister vent valve is ON Less than 0.286 kPa (2.25 mmHg)