DTC P043E Evaporative Emission System Leak Detection Reference Orifice Low Flow
DTC P043F Evaporative Emission System Reference Orifice High Flow
DTC SUMMARY
| DTCs | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timing | Detection Logic |
| P043E | Reference orifice clogged | Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine leak criterion. 0.02 inch leak criterion measured at start and at end of leak check. If system pressure lower than -4.85 kPa (-36.38 mmHg)*, ECM determines that reference orifice has clogging malfunction. |
| While ignition switch OFF | 2 trip |
| P043F | Reference orifice high-flow | Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine leak criterion. 0.02 inch leak criterion measured at start and at end of leak check. If system pressure higher than -1.06 kPa (-7.95 mmHg)*, ECM determines that reference orifice has high-flow malfunction. |
| While ignition switch OFF | 2 trip |
The values described in the table above are based on an atmospheric pressure of 100 kPa (750.1 mmHg) (absolute pressure).
- HINT:
- The reference orifice is located inside the canister pump module.
DESCRIPTION
The circuit description can be found in the Evaporative Emission (EVAP) system (Click here).MONITOR DESCRIPTION
5 hours* after the ignition switch is turned OFF, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.- HINT:
- *: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned OFF, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned OFF, the monitor check starts 2.5 hours later.
| Sequence | Operations | Descriptions | Duration |
| - | ECM activation | Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak criterion (reference pressure) measurement | In order to determine leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 900 seconds, ECM cancels EVAP system monitor. | 900 seconds* |
| D | Purge VSV monitor | Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak criterion (reference pressure) measurement | After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking. | 60 seconds |
| F | Final check | Atmospheric pressure measured and then monitoring result recorded by ECM. | - |

- P043E: Reference orifice clogged
In operation B, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM using the canister pressure sensor to determine the 0.02 inch leak criterion. If the pressure is lower than -4.85 kPa (-36.38 mmHg)*, the ECM interprets this as a clog malfunction in the reference orifice, and stops the EVAP system monitor. The ECM then illuminates the MIL and sets the DTC (2 trip detection logic).
*: The threshold varies according to the atmospheric pressure measured in operation A. The value described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.
- P043F: Reference orifice high-flow
In operation B, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM using the canister pressure sensor to determine the 0.02 inch leak criterion. If the pressure is higher than -1.06 kPa (-7.95 mmHg)*, the ECM interprets this as a high-flow malfunction in the reference orifice, and stops the EVAP system monitor. The ECM then illuminates the MIL and sets the DTC (2 trip detection logic).
*: The threshold varies according to the atmospheric pressure measured in operation A. The value described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.
MONITOR STRATEGY
| Required Sensors/Components | Canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 2 min. (varies with amount of fuel in tank) |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever these DTCs are not present | None |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or higher |
| Vehicle speed | Less than 2.5 mph (4 km/h) |
| Ignition switch | OFF |
| Time after key off | 5 or 7 or 9.5 hours |
| EVAP pressure malfunction (P0450, P0452, P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before key off | Condition 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
Key-off monitor sequence 1 to 8
| Next sequence is run if the following condition is met | - |
| Atmospheric pressure change | Within 0.3 kPa (2.25 mmHg) in 1 second |
| Next sequence is run if the following conditions set | - |
| EVAP pressure just after reference pressure measurement start | -1 kPa (-7.5 mmHg) or lower |
| Reference pressure | -4.85 to -1.05 kPa (-36.38 to -7.93 mmHg) |
| Reference pressure | Saturated |
| Next sequence is run if the following conditions set | - |
| EVAP pressure change after vent valve is ON | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following conditions set | - |
| EVAP pressure | Saturated within 900 seconds |
| Next sequence is run if the following conditions set | - |
| EVAP pressure change after purge valve is open | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following conditions set | - |
| EVAP pressure just after reference pressure measurement | -1 kPa (-7.5 mmHg) or lower |
| Reference pressure | -4.85 to -1.05 kPa (-36.38 to -7.93 mmHg) |
| Reference pressure | Saturated within 55 seconds |
| Difference between first reference pressure and second reference pressure | Less than 0.7 kPa (5.25 mmHg) |
| Next sequence is run if the following conditions set | - |
| EVAP pressure when vacuum introduction is complete | Lower than second reference pressure |
| EVAP monitor is complete if the following conditions set | - |
| Atmospheric pressure difference between sequence 1 and 8 | Within 0.3 kPa (2.25 mmHg) |
TYPICAL MALFUNCTION THRESHOLDS
"Saturated" indicates that the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) in 30 seconds.| One of following conditions met | - |
| FTP when just after reference pressure measurement started | -1 kPa (-7.5 mmHg) or higher |
| Reference pressure | -4.85 kPa (726 mmHg) or lower |
| Reference pressure | -1.05 kPa (754 mmHg) or higher |
| Reference pressure | Not saturated within 60 seconds |
| Difference between first reference pressure and second reference pressure | 0.7 kPa (5.25 mmHg) |