Toyota
4Runner GRN210 215 UZN210 215
Repair Manual
2Uz-Fe Engine Control System
Sfi System
Read value of intelligent tester (engine coolant temperature)
Read value of intelligent tester (check for open in wire harness)
Read value of intelligent tester (check for short in wire harness)
DTC P0115 Engine Coolant Temperature Circuit
DTC P0117 Engine Coolant Temperature Circuit Low Input
DTC P0118 Engine Coolant Temperature Circuit High Input
DESCRIPTION
- A thermistor is built into the Engine Coolant Temperature (ECT) sensor and changes the resistance value according to the engine coolant temperature.
The structure of the sensor and connection to the ECM is the same as the Intake Air Temperature (IAT) sensor.- HINT:
- If the ECM detects the DTC P0115, P0117 or P0118, it operates the fail-safe function in which the ECT is assumed to be 80°C (176°F).
| DTC No. | Proceed to | DTC Detection Condition | Trouble Area |
| P0115 | Step 1 | Open or short in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds |
|
| P0117 | Step 4 | Short in ECT sensor circuit for 0.5 seconds |
|
| P0118 | Step 2 | Open in ECT sensor circuit for 0.5 seconds |
|
- HINT:
- After confirming DTC "P0115, P0117 or P0118", use the intelligent tester to confirm the engine coolant temperature in the "DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL".
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or more | Short circuit |
MONITOR DESCRIPTION
The Engine Coolant Temperature (ECT) sensor is used to monitor the engine coolant temperature. The ECT sensor has a thermistor that varies its resistance depending on the temperature of the engine coolant. When the coolant temperature is low, the resistance in the thermistor increases. When the temperature is high, the resistance drops. The variations in resistance are reflected in the voltage output from the sensor. The ECM monitors the sensor voltage and uses this value to calculate the ECT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a fault in the ECT sensor and sets a DTC.Example:
When the ECM calculates that the ECT is -40°C (-40°F) (P0118) or more than 140°C (284°F) (P0117) and if either condition continues for 0.5 seconds or more, the ECM will set a DTC.
MONITOR STRATEGY
| Related DTCs | P0115: ECT sensor range check (fluttering) P0117: ECT sensor range check (low resistance) P0118: ECT sensor range check (high resistance) |
| Required Sensors/Components (Main) | ECT sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
TYPICAL ENABLING CONDITIONS
| Monitor will run whenever these DTCs are not present | None |
| The typical enabling condition is not available | - |
TYPICAL MALFUNCTION THRESHOLDS
| ECT sensor voltage [Engine coolant temperature] | Less than 0.14 V, or more than 4.91 V (More than 140°C (284°F), or less than -40°C (40°F)) |
| ECT sensor voltage [Engine coolant temperature] | Less than 0.14 V (More than 140°C (284°F)) |
| ECT sensor voltage [Engine coolant temperature] | More than 4.91 V (Less than -40°C (-40°F)) |
COMPONENT OPERATING RANGE
| ECT sensor voltage [ECT] | 0.14 V (140°C (284°F)) to 4.91 V (-40°C (-40°F)) |
WIRING DIAGRAM

INSPECTION PROCEDURE
- HINT:
- If other DTCs relating to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
Connect the intelligent tester to the DLC3 with CAN VIM.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / COOLANT TEMP.
Read the values.
- Standard:
- Same value as the actual ECT.
- Result:
Engine Coolant Temperature Proceed to -40°C (-40°F) A 140°C (284°F) or more B OK (same as present temperature) C
- HINT:
- If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
- If there is a short circuit, the intelligent tester indicates 140°C (284°F) or more.
| Go to step 4 | |||
| CHECK FOR INTERMITTENT PROBLEMS | |||
| A | |
![]() |

Disconnect the E2 Engine Coolant Temperature (ECT) sensor connector.
Connect terminals 1 and 2 of the ECT sensor wire harness side connector.
Connect the intelligent tester to the CAN VIM. Then connect the CAN VIM to the DLC3.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / COOLANT TEMP.
Read the value.
- Standard:
- 140°C (284°F) or more
Reconnect the ECT sensor connector.
| CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE ENGINE COOLANT TEMPERATURE SENSOR | |||
| NG | |
![]() |

Disconnect the E2 ECT sensor connector.
Connect terminals THW and E2 of the E4 ECM connector.
- HINT:
- Before checking, do a visual and contact pressure check for the ECM connector.
Connect the intelligent tester to the DLC3 with CAN VIM.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / COOLANT TEMP.
Read the value.
- Standard:
- 140°C (284°F) or more
Reconnect the ECT sensor connector.
| CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM | |||
| OK | |
![]() | |
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |

Disconnect the E2 ECT sensor connector.
Connect the intelligent tester to the DLC3 with CAN VIM.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / COOLANT TEMP.
Read the value.
- Standard:
- -40°C (-40°F)
Reconnect the ECT sensor connector.
| REPLACE ENGINE COOLANT TEMPERATURE SENSOR | |||
| NG | |
![]() |

Disconnect the E2 ECT sensor connector.
Disconnect the E4 ECM connector.
Connect the intelligent tester to the DLC3 with CAN VIM.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / COOLANT TEMP.
Read the value.
- Standard:
- -40°C (-40°F)
Reconnect the ECT sensor connector.
Reconnect the ECM connector.
| REPLACE ECM | |||
| OK | |
![]() | |
| REPAIR OR REPLACE HARNESS OR CONNECTOR | |



